Shagang Volkswagen Anjing Second Factory Napotec ADR Drum Replacement Project

2026.08.24 321

Project location: An Ting II Factory, Jiading District, Shanghai

Number of rotors: 1 set

Model: 4500-400

Type of exhaust gas: Spray painting exhaust gas

Reason for replacement: The old ADR rotor failed to meet the treatment efficiency standards

Original manufacturer of ADR: Western Technology Research Institute

Time of use before replacement: Less than 5 years

Replacement date: October 2020


Main situation:


 图片1.png2.png

图1是现场拆卸旧ADR时的照片

4.png3.png

Figure 2 shows the photo taken during the on-site installation of the new ADR.

Post-replacement operation results:

On-site outlet online monitoring data (Environmental Protection Bureau): < 5 mg/m3

Handheld analyzer (PID, on-site): < 5 mg/m3

Online GC-FID test inlet concentration (SGS): 516 mg/m3

Online GC-FID test (SGS): 4.8 mg/m3

Rotary disc treatment efficiency: 99.07%


Test results:

 图片2.png

ScreenShot_2026-08-24_160239_244.png

One month after replacing the old on-site rotors (ADR) with Napotec rotors, the imported VOCs concentrations at the inlet and outlet of the rotors were measured by SGS. 

In terms of services: Naboco has formulated an efficient and reasonable replacement plan for SAIC Volkswagen, with a replacement cycle of 6 days, meeting the production needs of the customers.


Open Cooperation Channels, Cultivate the Environmental Protection Field Together

Whether you need equipment selection, technical consultation, or win-win cooperation, the Napotec professional team is always at your service.